+LSI Corp. MegaRAID StorCLI Release
+
+*********************************************
+
+Release Date: 10/07/14
+========================
+
+Supported Controllers
+==================
+
+MegaRAID SAS 9361-8i
+MegaRAID SAS 9361-4i
+MegaRAID SAS 9341-8i
+MegaRAID SAS 9341-4i
+MegaRAID SAS 9380-8e
+MegaRAID SAS 9380-4i4e
+MegaRAID SAS 9270-8i
+MegaRAID SAS 9271-4i
+MegaRAID SAS 9271-8i
+MegaRAID SAS 9271-8iCC
+Syncro CS 9271-8i
+MegaRAID SAS 9286-8e
+MegaRAID SAS 9286CV-8e
+MegaRAID SAS 9286CV-8eCC
+Syncro CS 9286-8e
+MegaRAID SAS 9265-8i
+MegaRAID SAS 9285-8e
+MegaRAID SAS 9240-4i
+MegaRAID SAS 9240-8i
+MegaRAID SAS 9260-4i
+MegaRAID SAS 9260CV-4i
+MegaRAID SAS 9260-8i
+MegaRAID SAS 9260CV-8i
+MegaRAID SAS 9260DE-8i
+MegaRAID SAS 9261-8i
+MegaRAID SAS 9280-4i4e
+MegaRAID SAS 9280-8e
+MegaRAID SAS 9280DE-8e
+MegaRAID SAS 9280-24i4e
+MegaRAID SAS 9280-16i4e
+MegaRAID SAS 9260-16i
+MegaRAID SAS 9266-4i
+MegaRAID SAS 9266-8i
+MegaRAID SAS 9285CV-8e
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 10/07/14
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.13.06
+Previous Versoin       1.12.13
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+Linux-ppc
+VMware
+VMware MN
+VMware MN-NDS
+Solaris x86
+FreeBSD
+EFI
+Ubuntu
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+** Change list updated 10/07/14 -- no change to binaries **
+SCGCQ00637551 - (Closed) - storcli.efi /c0 set migraterate is setting values even if the value is out of range
+SCGCQ00698962 - (Closed) - Storcli /c0 show configautobalance display as OFF eventhought the feature is ON
+SCGCQ00704313 - (Closed) - Legacy command for displaying LD information not working
+SCGCQ00712596 - (Closed) - Storcli not able to show the pinned cache for 240 VDs
+SCGCQ00713774 - (Closed) - STORCLI fail to execute Reconstruction with Degraded r6 VD
+SCGCQ00717299 - (Closed) - Storecli expand array OCE Not possible, insufficient space, expand array to get the additional space
+SCGCQ00725544 - (Closed) - Supercap properties reports wrong in storcli
+SCGCQ00726485 - (Closed) - Commands for unintended controller during OCR, controller availability non transparent during OCR.
+SCGCQ00735055 - (Closed) - Mismatch in the no of fields showing in /c0 show eventloginfo command according to the help file
+SCGCQ00738817 - (Closed) - Incorrectness in auto patrol read starttime schedule, after changing the date.
+SCGCQ00739945 - (Closed) - need to remove AWB option with creation of Cachecade vd from Helpfile
+SCGCQ00740053 - (Closed) - storlci becomes unresponsive on trying to create multiple VD at a time.
+SCGCQ00688530 - (Closed) - Not able to unhide individual VD's and DG hide/unhide does not work when one vd is hidden or unhidden in DG
+SCGCQ00693466 - (Closed) - "Segmentation fault" Error message after executing Diagnostic cmd in storCLI and further execution resulting into PSOD
+SCGCQ00705623 - (Closed) - Unsupported-command error on executing the command to set MFG data on controller in EFI shell .
+SCGCQ00710783 - (Closed) - Detail-status is not required to be displayed for any command which is success
+SCGCQ00720007 - (Closed) - Caching is not getting enabled on all SVD's at a time using StorCLI command
+SCGCQ00735327 - (Closed) - using option 2 for join mirror performs the same operation as option 0
+SCGCQ00686189 - (Closed) - Advance Software options is not displaying any value for MegaRAID CacheCade Pro2.0
+SCGCQ00705593 - (Closed) - Command "show autopdcache ?" is not working correctly
+SCGCQ00720446 - (Closed) - Show learn is not coming in Help File
+SCGCQ00740182 - (Closed) - Showing incorrect VDs number after excluding the VDs from cc
+SCGCQ00635336 - (Closed) - storcli /c0 set backplane mode=val if we give value 256 its taking as 0 and giving command as success.
+SCGCQ00684010 - (Closed) - For iBBU battery typeiBBU09 the Next Learn time value is not correct in the output of storCLI command storcli64 /c0/bbu show
+SCGCQ00687566 - (Closed) - Storcli error message is confusing
+SCGCQ00691917 - (Closed) - on querying for backplane/controller PHY, errors get reported
+SCGCQ00723767 - (Closed) - Incorrectness in Ctrl_Prop While getting output for /c0 show prcorrectunconfiguredareas
+SCGCQ00693177 - (Closed) - Try to split mirror with /c0/dall split mirror, But split mirror is not happening on all vds.
+SCGCQ00693187 - (Closed) - not giving detail status table for split mirror command.
+SCGCQ00695247 - (Closed) - on querying the PHY info for the drive,storcli gives the junk data
+SCGCQ00723938 - (Closed) - storcli is giving improper error message when i missed pdperarray while creating raid00
+SCGCQ00731998 - (Closed) - StorCLI displaying unwanted fields for Non-Controller flash image.
+SCGCQ00694027 - (Closed) - on querying the phy error counter for controller, storcli dosent fail the cmd
+SCGCQ00709767 - (Closed) - 'disableCacheBypass' being treated inversely as 'cacheBypass'
+SCGCQ00668543 - (Closed) - Not able to enable security on DG which are eligible for secured Drive Group
+SCGCQ00705597 - (Closed) - Help is not present for "set autopdcache".
+SCGCQ00711678 - (Closed) - Help of set consistency check showing special character
+SCGCQ00716639 - (Closed) - Storcli TMM and SCAP info shows wrong numbers
+SCGCQ00606760 - (Closed) - "set perfmode" accepting wrong inputs
+SCGCQ00642227 - (Closed) - Implement Head of Queue drive rebuild for MegaRAID controllers
+SCGCQ00656613 - (Closed) - Add ability to take a VD offline, bring back VD online
+SCGCQ00684957 - (Closed) - Need StorCLI-O for EFI
+SCGCQ00707449 - (Implemented) - SSHA Licensing (PFK)
+SCGCQ00709946 - (Active) - For iBBU battery typeiBBU09 the Next Learn time value is not correct in the output of storCLI command storcli64 /c0/bbu show
+SCGCQ00719104 - (Port_Complete) - Missing learn cycle progress information in show learn command for cachevault.
+SCGCQ00699266 - (Port_Complete) - storcli is displaying only information of one enclosure when all option is given for phyerrorcounters, on multiple enclosures
+SCGCQ00722165 - (Active) - Liberator (SAS9260-8i) controllers indicate that the do not support JBOD mode
+SCGCQ00690644 - (Port_Complete) - storcli.efi /c0 set migraterate is setting values even if the value is out of range
+SCGCQ00732184 - (Active) - CLI command to access/modify Drive Activity LED
+SCGCQ00731753 - (Active) - CLI command to access/modify Immediate IO
+SCGCQ00690877 - (Port_Complete) - Advance Software options is not displaying any value for MegaRAID CacheCade Pro2.0
+SCGCQ00691901 - (Port_Complete) - Not able to enable security on DG which are eligible for secured Drive Group
+
+
+Installation Commands:
+=======================
+Any OS specific instructions are noted in a readme file included in a folder in the zip file.
+Refer to the MegaRAID SAS Software User's Guide for any additional StorCLI information.  The User Guide can be found in the MegaRAID Documentation section of www.lsi.com.
+
+
+=======================
+Previous Releases
+=======================
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 08/08/14
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.12.13
+Previous Versoin       1.09.13
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+Solaris x86
+FreeBSD
+EFI
+Ubuntu
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+SCGCQ00617622 - (Closed) - Storcli- Gives Seg fault for './storcli /c0 show all' if a foreign Secured VD is present on the controller
+SCGCQ00637551 - (Closed) - storcli.efi /c0 set migrate rate is setting values even if the value is out of range
+SCGCQ00648409 - (Closed) - Value not popped up for successful completion of autopdcache=r0 command.
+SCGCQ00649340 - (Closed) - Store add VD help should display R1 EC as supported raid level
+SCGCQ00657399 - (Closed) - query for multiple enclosure properties is failing in storcli version-1.12.05
+SCGCQ00659228 - (Closed) - storcli show file=***.rom displaying only firmware version
+SCGCQ00668210 - (Closed) - Inconsistent scheduled learn time.
+SCGCQ00672888 - (Closed) - Junk Characters observed in EFI storcli version : 1.12.07
+SCGCQ00678562 - (Closed) - the phy number dosent come properly on querying the phy error counter
+SCGCQ00606774 - (Closed) - command "set patrolread delay" showing negative time delay
+SCGCQ00622402 - (Closed) - Changing the MR_MFC_DEFAULTS->biosContinueOnError behavior for StorCLI as per PDMs
+SCGCQ00624834 - (Closed) - fw is not able create vd on all drive as r0 using storcli command without an option immediate
+SCGCQ00624991 - (Closed) - there is no syntax for storcli64.exe /cx/ex show
+SCGCQ00629272 - (Closed) - storcli /c0/v2-256 show results in segmentation fault
+SCGCQ00644238 - (Closed) - improper statment for emulationType 0 in help & detailed help
+SCGCQ00647260 - (Closed) - Storcli-1.12.03-a failure message is displayed for a successful operation
+SCGCQ00653749 - (Closed) - "cfgcachecadedsply" command is not showing any CC VD details [when creating using EVS + CCVD]
+SCGCQ00611955 - (Closed) - Update the storcli help file for this command ./stocli /c0 set eccbucketleakrate
+SCGCQ00616901 - (Closed) - seeing junk characters for command "show termlog"
+SCGCQ00626582 - (Resolved) - not able to create WB cachecade-VD
+SCGCQ00627824 - (Closed) - -High Availability Properties alignment properly in adpallinfo detail.
+SCGCQ00627826 - (Closed) - not able set emergency hotspare field in storcli
+SCGCQ00646216 - (Closed) - Help not displayed for diag when tagged with paniclog,smartlog and errorlog.
+SCGCQ00647107 - (Closed) - LD emulation type set to 512e even though there only 512n drives are used during creation
+SCGCQ00682484 - (Closed) - help file needs to be updated  for /cx/dx add mirror src=2
+SCGCQ00684010 - (Closed) - For iBBU battery typeiBBU09 the Next Learn time value is not correct in the output of storCLI command storcli64 /c0/bbu show
+SCGCQ00691917 - (Closed) - on querying for backplane/controller PHY, errors get reported
+SCGCQ00645141 - (Closed) - Storcli reports VD state as offline if pinned cache is generated through CC VD removal
+SCGCQ00646223 - (Closed) - adding mirror by setting src value to 0 will start rebuild on online drive
+SCGCQ00649337 - (Closed) - Junk characters seen in storcli.efi –adpallinfo –a0 and storcli.efi /c0 show all
+SCGCQ00695247 - (Closed) - on querying the PHY info for the drive,storcli gives the junk data
+SCGCQ00666644 - (Closed) - using option 2 i.e ./storcli /c0/d0 add mirror src=2 give success but no operation is performed
+SCGCQ00694027 - (Closed) - on querying the phy error counter for controller, storcli dosent fail the cmd
+SCGCQ00615654 - (Closed) - Battery serial number is not coming properly as per termlogs
+SCGCQ00627716 - (Closed) - unable to create VD using Storcli
+SCGCQ00646344 - (Closed) - Overall Health of a controller is displayed as ERROR if there is no VD present.
+SCGCQ00658427 - (Closed) - Need to handle the failed cases and junk/invalid image file scenario for storcli show file=<filename> command
+SCGCQ00675388 - (Closed) - Storcli won't set cacheflushinterval to a value greater >= 10 using old megacli syntax
+SCGCQ00670246 - (Closed) - add vd each type=r0 creation leads to Segmentation Fault
+SCGCQ00678558 - (Closed) - the out put for phyerror counter goes beyound the limit of wordcount.
+SCGCQ00678616 - (Closed) - Status of storcli controller show health command on card Failed
+SCGCQ00621291 - (Closed) - Add storCLI command to read phy error counters (target, expander, controller)
+SCGCQ00625566 - (Closed) - Add a feature to read and display the FW version from the .rom file for MegaRAID FW package
+SCGCQ00634751 - (Closed) - Requirement for 512e implementation changes
+SCGCQ00673086 - (Closed) - OAdd SSHA support to StorCLI
+SCGCQ00610100 - (Port_Complete) - implemented the below commands for supporting limitsatato3G
+SCGCQ00615523 - (Port_Complete) - doesn't have proper keyword to set the Dimmer switch property for DisableLDPS.
+SCGCQ00631409 - (Port_Complete) - Add support bit check for flash-erase.
+SCGCQ00654713 - (Port_Complete) - Help not displayed for diag when tagged with paniclog,smartlog and errorlog. - (SCGCQ00646216) --Updating review comments
+SCGCQ00615522 - (Port_Complete) - displays 'Model' information incorrectly using PercCLI show
+SCGCQ00626649 - (Port_Complete) - storcli /253-255 show gives segmentation fault.
+SCGCQ00660446 - (Port_Complete) - WB CCVD is created eventhough WT is specified in Slice nytro Cache create option
+SCGCQ00629199 - (Port_Complete) -  unable to create VD using Storcli
+SCGCQ00615442 - (Port_Complete) - Porting OverProvisioning and Remanufacture to StorCli5.9 for NMR 1.8
+SCGCQ00631330 - (Port_Complete) - set batterywarning command sets inproperly.
+SCGCQ00631410 - (Port_Complete) - SSDThermalPollInterval value range starts from 1 not from 0
+SCGCQ00614724 - (Port_Complete) - add VD nytrocache command displays a wrong error message if the CCVD is already present
+SCGCQ00614177 - (Port_Complete) - StorCli Displays Incorrect Information for BatteryWarning versus MagaCli
+SCGCQ00631411 - (Port_Complete) - Implemented the personality mgmt to set either HBA/RAID mode.
+SCGCQ00670865 - (Port_Complete) - NMR1.8-Storcli shows success message on creating EC CCVD in WT mode
+SCGCQ00691901 - (Port_Complete) - Not able to enable security on DG which are eligible for secured Drive Group
+SCGCQ00690877 - (Port_Complete) - Advance Software options is not displaying any value for MegaRAID CacheCade Pro2.0
+SCGCQ00611864 - (Port_Complete) - Porting megaSCu syntax to perccli for limitMaxRateSATAto3G
+SCGCQ00611866 - (Port_Complete) - Implemented the commands for ThermalPoll interval for SSD and HDD
+SCGCQ00615271 - (Port_Complete) - StorCLIF and StorCLIO - Porting VC features
+SCGCQ00670863 - (Port_Complete) - Source VD association failed and Storcli application crashed while associating sourceVD to CCVD
+
+
+Installation Commands:
+=======================
+Any OS specific instructions are noted in a readme file included in a folder in the zip file.
+Refer to the MegaRAID SAS Software User's Guide for any additional StorCLI information.  The User Guide can be found in the MegaRAID Documentation section of www.lsi.com.
+
+
+
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 06/18/14
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.09.13
+Previous Versoin       1.09.08
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+Solaris x86
+FreeBSD
+EFI
+Ubuntu
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+SCGCQ00681802 - (Completed) - GG firmware update patch (GG firmware update support for following OSes: Windows, Linux, EFI, Ubuntu)
+SCGCQ00681722 - (Closed) - storcli (megacli style) output difference in pdlist command
+SCGCQ00682462 - (Closed) - Help file should be updated
+SCGCQ00655156 - (Closed) - "storcli -AdpBIOS -BE -a0" no longer works
+SCGCQ00682485 - (Closed) - status of the command id getting success with invalid GG file.
+SCGCQ00682477 - (Closed) - option "Resetnow" should be blocked when flashing Gasguage
+SCGCQ00698740 - (Closed) - Card with Empty module version doesn't update firmware if option "noverchk" is provided.
+SCGCQ00683236 - (Closed) - In Rhel OS seeing wrong error code.
+SCGCQ00658495 - (Port_Complete) - set batterywarning command sets inproperly.
+SCGCQ00659836 - (Port_Complete) - StorCli Displays Incorrect Information for BatteryWarning versus MagaCli
+
+
+Installation Commands:
+=======================
+Any OS specific instructions are noted in a readme file included in a folder in the zip file.
+Refer to the MegaRAID SAS Software User's Guide for any additional StorCLI information.  The User Guide can be found in the MegaRAID Documentation section of www.lsi.com.
+
+
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 05/09/14
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.09.08
+Previous Versoin       1.07.07
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+Solaris x86
+FreeBSD
+EFI
+Ubuntu
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+SCGCQ00567786 - (Closed) - not able get enclosure status
+SCGCQ00571823 - (Resolved) - Added a condition to check for no VDs in StrtDrCp
+SCGCQ00573703 - (Closed) - Storcli shows wrong VD size for 4K VDs during foreign config import
+SCGCQ00574165 - (Closed) - compare factorysettings is a factory command but works in storcli
+SCGCQ00579423 - (Closed) - storcli - issung "storcli /c0/v256" command generating coredump segmentation fault
+SCGCQ00600059 - (Closed) - Storcli creates configuration not using the OEM default value for Disk Cache Policy
+SCGCQ00471826 - (Closed) - StorCli mbox value needs to be changed for the command "storcli /c0/bbu show gasgauge offset=1 numbytes=1"
+SCGCQ00571832 - (Resolved) - Added a condition to check for no VDs
+SCGCQ00574325 - (Closed) - Storcli 'show ds' command fails with message "LD Power saving is unsupported"
+SCGCQ00598687 - (Closed) - for bbu command In properties schedule time is showing twice
+SCGCQ00599761 - (Closed) - storcli /c0/e1,2,3 show is showing enclouser properties multiple times.
+SCGCQ00622402 - (Closed) - Changing the MR_MFC_DEFAULTS->biosContinueOnError behavior for StorCLI as per PDMs
+SCGCQ00484361 - (Closed) - Removed the option all from tokenizer as it is not supported for enclosure firmware download.
+SCGCQ00563031 - (Closed) - Even though there are no drive groups, the command storcli /c0/dxxx set security=on is getting success
+SCGCQ00565409 - (Closed) - while Rebuild was going on Storcli was allows to create a partial VD on the same drive group
+SCGCQ00576233 - (Closed) -  ./storcli64 /c0/bbu set learnstarttime command is failing with segmentation fault
+SCGCQ00595061 - (Closed) - Storcli shows wrong estimated time for a rebuilding drive.
+SCGCQ00602401 - (Closed) - ./storcli64 /c0/e252 show status displays success message
+SCGCQ00581367 - (Closed) - MOn issuing command Adpalilog -a0 the Storcli throws an error 0x0c on PPC server
+SCGCQ00601834 - (Closed) - The SCAPVPD commands are described as BBU instead of CV.
+SCGCQ00559492 - (Closed) - Storcli displays the cc estimated time left out for the vd's where the operation is not in progress
+SCGCQ00573720 - (Closed) - Need to display skipped images by storcil package flashing
+SCGCQ00574205 - (Closed) - ./storcli64 /c252 show is displaying controller information of 1st controller
+SCGCQ00601212 - (Closed) - Detailed help for storcli /c0/v0 set hostaccess is not showing
+SCGCQ00581982 - (Closed) - Difference in behaviour across windows and linux platform after flashing FW from storclif
+SCGCQ00598488 - (Closed) - storcli /c256 show is showing O/P as wrong synatx.
+SCGCQ00600176 - (Closed) - command "/c0/p8 show" causing cli crash in windows OS
+SCGCQ00602926 - (Closed) - when we query help for set perfmode the range is not mentioned for maxflush lines & numiostoorder.
+SCGCQ00606117 - (Closed) - storlib library depended Make file flags check in
+SCGCQ00577682 - (Closed) - MR Liberator :: ./storcli64 /c0 show dequeuelog file command failing with segmentation fault
+SCGCQ00588916 - (Resolved) - ./storcli64 /c0/sall show rebuild command shows success status
+SCGCQ00598788 - (Closed) - "show termlog" command description is coming after displaying the logs.
+SCGCQ00627716 - (Closed) - unable to create VD using Storcli
+SCGCQ00553006 - (Closed) - Updated Help syntax for add vd w.r.t AWB
+SCGCQ00572149 - (Closed) - Added the help changes for break and join mirror.
+SCGCQ00601568 - (Closed) - nolog option is not working in MegaCLI
+SCGCQ00526855 - (Implemented) - Link libstdc++ statically to Linux versiosn of Strcli, storclio and storclif
+SCGCQ00602432 - (Closed) - Linux-ppc 32-bit minimum driver version supported by storcli 06.603.04.00.
+SCGCQ00554055 - (Closed) - Big endian architecture support for MR Linux driver and StorCli
+SCGCQ00555468 - (Closed) - Added OEM based help and displaying it.
+SCGCQ00568855 - (Implemented) - Added new commands for join mirror
+SCGCQ00550374 - (Implemented) - Added new commands for break mirror
+SCGCQ00569363 - (Closed) - Implemented the below CS syncro commands
+SCGCQ00564470 - (Implemented) - Request RAID CLI to display the Patrol Read Start Time
+SCGCQ00523846 - (Implemented) - Storcli to flash 16 and 32 MB images
+SCGCQ00593583 - (Port_Complete) - In Storcli, appropriate error description to be logged when FW flash is failed
+SCGCQ00601765 - (Port_Complete) - Storcli shows wrong estimated time for a rebuilding drive.
+SCGCQ00576453 - (Port_Complete) - Found storli will show incorrect Next starttime after changing CC from Automatic to OFF.
+SCGCQ00592293 - (Port_Complete) - Unable to replace failed drive
+SCGCQ00598800 - (Port_Not_Required) - StorCLI adpalilog command crashes in Windows 2012 R2 Build 9600 - version 1.06.03 and version 1.03.46
+SCGCQ00558870 - (Port_Complete) - Implemented the deviceExposure as a BIOS option to set /c0 set BIOS deviceExposure=n
+SCGCQ00564130 - (Port_Complete) - Added a condition to check for number of drives.
+SCGCQ00604174 - (Active) - BiosContinueOnError IssueWebBIOS for SAS9265-8i controller incorrectly reports "Pause on errors" instead of "Bypass Error"
+SCGCQ00593384 - (Port_Complete) - SCSI bus reset while collecting TFF smart logs
+SCGCQ00593417 - (Port_Complete) - 1.05.56 rpm installation failed saying "scriptlet failed, exit status 1"
+SCGCQ00593572 - (Port_Complete) - TFF firmware upgrade succeeded with mode 7 on Eagle board
+SCGCQ00567735 - (Port_Complete) - not showing DS3 enable properties.
+SCGCQ00578982 - (Port_Complete) - and storclif mention "nytrocache" in help message not an OEM feature
+SCGCQ00593226 - (Port_Complete) - When attempting to update DFF firmware, update fails with error "Failure 1001 failed to get ssd Controller type.
+SCGCQ00593386 - (Port_Complete) - 'start format' command form stocli on unconfigured drive deletes all the vds configured
+SCGCQ00598815 - (Port_Complete) - StorCLI adpalilog command crashes in Windows 2012 R2 Build 9600 - version 1.06.03 and version 1.03.46
+SCGCQ00563046 - (Port_Complete) - storcli64.exe /c0/cv start learn option is not present
+SCGCQ00575400 - (Port_Complete) - Getting segmentation fault when executed the command /c0 compare factorysettings file= file name
+SCGCQ00555931 - (Port_Complete) - storclif 1.07.06 does not have memory scrub test available
+SCGCQ00567476 - (Port_Complete) - getting segmentation fault when executed the command /c0 set factory file=filename
+SCGCQ00578979 - (Port_Complete) - space present in command compare factorysettings between words factorysettings
+SCGCQ00593402 - (Active) - Successful command execution depicted as a "failure" for the command: "add each vd type=r0"
+SCGCQ00593571 - (Port_Complete) - Storcli doesn't provide "Description" in output when extract paniclog is issued on all the TFFs.
+SCGCQ00593568 - (Active) - Storcli doesnot prompt the user to reboot the host after changing the link speed of a TFF.
+
+
+Installation Commands:
+=======================
+Any OS specific instructions are noted in a readme file included in a folder in the zip file.
+Refer to the MegaRAID SAS Software User's Guide for any additional StorCLI information.  The User Guide can be found in the MegaRAID Documentation section of www.lsi.com.
+
+
+
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 01/20/14
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.07.07
+Previous Versoin       1.05.07
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+Solaris x86
+FreeBSD
+EFI
+Ubuntu
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+SCGCQ00493418 - (Closed) - FW breaks to MegaMon on executing "Cli /eall/sall show all" command.
+SCGCQ00501866 - (Closed) - Time Left is not show correctly by sparc storcli
+SCGCQ00521869 - (Closed) - /call/eall show not providing details of enclosure connected to the second controller
+SCGCQ00526799 - (Closed) - Not able to flash PD firmware of 4TB Drive using storcli
+SCGCQ00485777 - (Closed) - FW breaks to Megamon, after creating 16 R0 VD's and on executing command "cli /vall show all" from PCLI.
+SCGCQ00501376 - (Closed) - "/c0 show dequeuelog file=_____" command is not working in OS OEL_5.9
+SCGCQ00503993 - (Closed) - Command "./storcli /call/eall/sall show" fails for second controller with description drive not found.
+SCGCQ00505348 - (Closed) - The help file for "/c0 start Diag duration=___" is missing
+SCGCQ00503359 - (Closed) - Wrong PCLI version with junk charcters are displayed under GetControllerInfo.
+SCGCQ00498965 - (Closed) - "/c0/bbu start learn" command starts battery learn cycle on supercap battery.
+SCGCQ00518133 - (Closed) - LSI_MR Controllers fails to set "FACTORY SETTINGS"
+SCGCQ00526503 - (Closed) - Flashing of FW in UEFI mode using storcli.efi is issuing File read error.
+SCGCQ00501383 - (Closed) - "/c0 show dequeuelog file=_____" command is missing in main help file
+SCGCQ00501414 - (Closed) - Online firmware update is not triggered on flashing FW
+SCGCQ00524047 - (Closed) - Segmentation fault occures while converting binary to text file of DQlogs
+SCGCQ00526385 - (Closed) - Unable to create cachecade VD with WT property .
+SCGCQ00522666 - (Closed) - Command "cli /sall show all"
+SCGCQ00524755 - (Closed) - Storcli- Gives incomplete message while clearing config when CC VD is present on the controller
+SCGCQ00493544 - (Closed) - "Error! App exec failed in FW PCLIError! Internal" is displayed on executing "Cli /eall/sall spindown" command with 25 drives.
+SCGCQ00501437 - (Closed) - StorCLI - MR 6.2 StorCLI help syntax is wrong
+SCGCQ00518372 - (Closed) - Displaying the Adapter health status in storcli show.
+SCGCQ00501561 - (Closed) - Implemented the diag results to print on console
+SCGCQ00484168 - (Closed) - Implemented the AWB for VD creations
+SCGCQ00526393 - (Active) - Implementation of "MegaCli adpbbucmd schedulelearn [options.....] an" equivalent command in storcli
+SCGCQ00304999 - (Closed) - SWR- Retrieval of controller information fails .
+SCGCQ00305001 - (Closed) - storcli command- show DS displays wrong information for type4 and DS off
+SCGCQ00307493 - (Closed) - (RW LSIP200233165) Storcli: Reocurance should be spelled as reoccurrence in controller show all properties for PR and CC
+SCGCQ00307495 - (Closed) - Displaying the correct operating system for Windows 2012 Server
+SCGCQ00308671 - (Closed) - StorCLI is not showing correct driver version in Solaris 11
+SCGCQ00309347 - (Closed) - StorCli-SATA Drives "PRODUCT ID" its not showing properly.
+SCGCQ00312089 - (Closed) - Storcli- Not able to perform erase operation on a PD on VMWare 4.1 update 2
+SCGCQ00312319 - (Closed) - Storcli- Status of /pall set linkspeed is showing success eventhough the operation is failure on ESX 4.1 update 2
+SCGCQ00314106 - (Closed) - Remove all negative error codes
+SCGCQ00314585 - (Closed) - StorCli - Cache cade VD information page doesn't have any details for associated VDs.
+SCGCQ00322316 - (Closed) - Defect: Storcli-Controller show/set help page in that last line execute with Storcli Directory.
+SCGCQ00328184 - (Closed) - StorCLI2.0: "endCtlrPropUpdate failed 4" when changing the properties of patrolread
+SCGCQ00335239 - (Closed) - Virtual Drive properties(stripe size and size) got changed when VD is degraded
+SCGCQ00338301 - (Closed) - StorCLI : Not able to set BBU modes using legacy syntax in EFI Environment
+SCGCQ00341488 - (Closed) - stocli_EFI- In paged view the next line after "press enter to continue " should be displayed in next line
+SCGCQ00342056 - (Closed) - StorCLI - in command "./storcli show " 2 fields are not getting displayed ( 1. Host Name , 2. Operating System )
+SCGCQ00342074 - (Closed) - storcli should not depend on MFC_FEATURES instead check the other bits which indicates whether a particular feature is supported
+SCGCQ00342549 - (Closed) - spelling mistake of initialization in (background initialization)
+SCGCQ00343721 - (Cloned_EnhReq) - Drive /c0/ex/sx Hot Spare Information, displays array info under Dedicated Drive Group(s) = 0, 1
+SCGCQ00343907 - (Closed) - StorCLI_EFI: System halts while performing import preview with securitykey in EFI Environment
+SCGCQ00345525 - (Closed) - On performing an "add vd" with size provided in TB a decimal value is truncated to whole number as input.
+SCGCQ00349419 - (Closed) - storcli /c0 show all -----> driver version and driver name field is missing
+SCGCQ00350744 - (Closed) - ./storcli /c0/dall show -----> In the drive group info the alignment for global hot spare drive is improper.
+SCGCQ00352569 - (Closed) - Buffer overflow
+SCGCQ00360745 - (Closed) - StorCLI does not provide command to set HSM or HCOE SCGCQ00358662
+SCGCQ00362717 - (Closed) - storcli /c0/d0 show " in that legend missing for "Dgrd/pdgd/Onln/ofLn/Rbld"
+SCGCQ00363522 - (Closed) - storcli query for displaying controller properties is showing status , as failure.
+SCGCQ00364248 - (Closed) - StorCLI failed to delete a VD that is just created under Windows 2008
+SCGCQ00364622 - (Closed) - Reports wrong diskgroup size while querying controller level properties
+SCGCQ00381100 - (Closed) - MR: not able to create PRL11 using 96 drives.
+SCGCQ00462959 - (Closed) - Slow to create VD in HA Linux
+SCGCQ00464708 - (Closed) - Storcli display total number of VDs in a individual drive group properties.
+SCGCQ00466519 - (Closed) - StorCLI_6.1:The help file for "/c0 compare securitykey h" is missing
+SCGCQ00467119 - (Closed) - SWR_SLES_11_SP3_GM Release validation : In storCli " serial number and FW package Build " fields are showing blank
+SCGCQ00481532 - (Closed) - Msg comes for all /c0 show commands.
+SCGCQ00305002 - (Closed) - Storcli:Unable to update PD Firmware using Storcli in Vmware 5.0
+SCGCQ00310308 - (Closed) - Storcli -Format for Date/Time varies in show|show all controller properties .
+SCGCQ00313759 - (Closed) - Storcli:Unable to create Cachecade VD in Windows 8
+SCGCQ00314602 - (Closed) - StorCli - Cachecade VD information page should not display stripe size.
+SCGCQ00316677 - (Closed) - Logical and Physical sector size must be hidden when 512E feature is not supported
+SCGCQ00322262 - (Closed) - iMR_Inv:37 drives shown as unconfigured good in MegaCLI when "enable JBOD=0" in Ubuntu 12.04 32 bit OS
+SCGCQ00324797 - (Closed) - Serial Number of controller is not displayed for some controllers.
+SCGCQ00332212 - (Closed) - libsysfs custom implementation issue.
+SCGCQ00341418 - (Closed) - In the command O/P of <./storcli /c0 show all>"Driver Name" and "Driver Version"are NOT matching with actual name and version
+SCGCQ00342723 - (Closed) - It is displaying the driver version as driver name
+SCGCQ00344992 - (Closed) - In the command O/P of <./storcli /c0 show all>, ErrMsg 255 Failed to get Bus Info is displayed
+SCGCQ00348911 - (Closed) - Adapter 0: Failed to start SecureErase on Virtual Drive 0 in VMware_ESXi_5.1
+SCGCQ00353679 - (Closed) - StorCli-"/c0/eall/sall show"in that need to be describe the GHS/Onln/Offln/F
+SCGCQ00355536 - (Closed) - MegaCli and StorCli can not manage both Liberator (and prior) and TB controllers in the same system under FreeBSD with the mfi adn mrsas driver.
+SCGCQ00357653 - (Closed) - Removing static memory allocation and allocating memory dynamically in function stricmp in file Cutils.cpp
+SCGCQ00357913 - (Closed) - Update VD emulation feature in StorCLI Libmods module to sync with latest APIs.
+SCGCQ00359998 - (Closed) - Code clean up in libmods and sysefi files are added
+SCGCQ00360814 - (Closed) - StorCLI: Not able to set pr property includessds as onlymixed on Liberator cacheoffload controller
+SCGCQ00362421 - (Closed) - StorCLI: Not able to detect Liberator Controller on FreeBSD 9.0(64-bit)
+SCGCQ00364097 - (Closed) - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs
+SCGCQ00366000 - (Closed) - Storcli displays incomplete serial number for some SSDs
+SCGCQ00374979 - (Closed) - Storcli ld info command displays R10 vd Span Depth to 1.
+SCGCQ00469162 - (Closed) - In virtual drives information the Cac filed values are incorrect with regular VD's
+SCGCQ00476030 - (Closed) - while running I/O ,It's taking time to load the controller information.
+SCGCQ00312928 - (Closed) - Storcli- Abbreviation of UID should be mentioned in the output for /cx/fall show all
+SCGCQ00314122 - (Closed) - Missing characters in PD model display
+SCGCQ00317649 - (Closed) - Defect: StorCli-VD state "Dgrd'' is changed in the description-''dgrd''
+SCGCQ00326862 - (Closed) - FreeBSD support for MegaWare Cli
+SCGCQ00338688 - (Closed) - Storcli spelling mistakes and typos
+SCGCQ00343593 - (Closed) - Description for different Drive "State" like DHS, Ugood, Online need to be provided under Show Drive Information
+SCGCQ00363455 - (Closed) - The legend for the PD List table exceeds 80 char limit.
+SCGCQ00364735 - (Closed) - UEFI, the O/P of <storcli /c0 show all>"Current Controller Date/Time" & "Current System Date/time" are not in proper format
+SCGCQ00371445 - (Closed) - Vmware CLI fails to set the phy linkspeed
+SCGCQ00377364 - (Closed) - StorCli shows Power Saving Option as enabled, despite controller having power saving option completely disabled.
+SCGCQ00383043 - (Closed) - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.
+SCGCQ00394883 - (Closed) - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354"
+SCGCQ00396303 - (Resolved) - Cfgclr command fails without force option in Sparc OS
+SCGCQ00460861 - (Closed) - MR_Inv_6.1:StorCLI- Gives wrong message after battery retention test command is issued for Supercap FBU03
+SCGCQ00462885 - (Closed) - Need to remove storcli /cx show clusterenable and storcli /cx set clusterenable=<value> since FW did not support this in HA
+SCGCQ00466038 - (Closed) - MR_Inv_6.1:StoreCLI- StorCLI reports retention time as 0 for supercap FBU02 and FBU03
+SCGCQ00466251 - (Closed) - HA : StorCLI crash when update drive firmware
+SCGCQ00471042 - (Closed) - PCLI:Cant able to set securitykey for Controller and also VD name for VD(Takes as uppercharacter even if name given in lower)
+SCGCQ00485270 - (Closed) - StorCLI- unsupported CV operations for SuperCap 'set' needs to be removed
+SCGCQ00311990 - (Closed) - Removed unsupported property "Ra=Read Ahead Adaptive" from VD information.
+SCGCQ00314114 - (Closed) - sector size of PDs are shown as 512 KB which is wrong.
+SCGCQ00314128 - (Closed) - Add abbreviation description to all the PD states
+SCGCQ00318435 - (Cloned_EnhReq) - Porting of 1.0 PRs to storcli phase 2.5 (Libmods)
+SCGCQ00345372 - (Closed) - Storcli command "/cx show all" must display ROC temperature.
+SCGCQ00359629 - (Closed) - In paged view the text " Press Enter to continue" should be changed to " Press any key to Continue"
+SCGCQ00365950 - (Closed) - StorCLI cannot displays information for controller in Safe mode
+SCGCQ00442610 - (Closed) - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.
+SCGCQ00469179 - (Closed) - Aligning with FW for strip calculation for 4K drives
+SCGCQ00337962 - (Closed) - StorCLI: not able to save events in txt file in EFI environment
+SCGCQ00362216 - (Closed) - iMr_Fury_StorCli:4K Drive size shown wrong in Esxi4.1U3
+SCGCQ00365632 - (Closed) - PCI Info for FreeBSD needs to be indicated as "N/A"
+SCGCQ00379104 - (Closed) - Not able to get paged view of StorCLI output on VM-Ware Platform
+SCGCQ00438350 - (Closed) - Megacli crashes after invoking any command in SGI system with one 9280-8e and 2 quad port qlogic FC cards.
+SCGCQ00485561 - (Closed) - storclio set and get vpd gives a wrong output in failure case.
+SCGCQ00493690 - (Closed) - /var/tmp//installobaWVe/checkinstallrbaWVe: line 11: syntax error at line 22
+SCGCQ00481039 - (Closed) - option -v doesn't work with preboot storcli
+SCGCQ00311436 - (Closed) - Storcli-SWR- Controller serial number display is different in show/showall controller properties .
+SCGCQ00360040 - (Closed) - Storcli is returning error with show
+SCGCQ00408070 - (Closed) - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD
+SCGCQ00423832 - (Closed) - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot
+SCGCQ00470976 - (Closed) - Storcli shows irrelevant information about Nytro cache VD when user types "CfgCacheCadeDsply"
+SCGCQ00484372 - (Closed) - Storcli:Help file modification required for command ''/cx set eghs''
+SCGCQ00357263 - (Closed) - MegaCLI adpgetpciinfo returns a static Bus Number value "17d0"
+SCGCQ00362070 - (Closed) - iMr_Fury_StorCLi:SectorSize show as "512KB" for 512Bytes drives
+SCGCQ00396665 - (Closed) - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.
+SCGCQ00397663 - (Closed) - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400
+SCGCQ00424978 - (Closed) - Is VD Emulated=Yes when emulationType=1
+SCGCQ00436107 - (Closed) - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected
+SCGCQ00448094 - (Closed) - core dump while issuing storcli command ./storcli /c0/fall show all.
+SCGCQ00454971 - (Closed) - storcli /c0 show is not listinf SWR controller
+SCGCQ00471978 - (Closed) - Storcli does not show firmware version using Megacli syntax
+SCGCQ00472000 - (Closed) - Storcli:"storcli /c0/v0 del help" does not show information on normal vd delete
+SCGCQ00314119 - (Closed) - "Drive NCQ setting" field Removed
+SCGCQ00357948 - (Closed) - StorCLI does not display drive information behind the Blackjack (Alta) interposer correctly
+SCGCQ00384644 - (Closed) - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K
+SCGCQ00413789 - (Closed) - storcli crashes on having a non PI drive and trying to create pi vd on all the drive
+SCGCQ00442652 - (Closed) - SWR_1.34 - Serial number field is blank in controller information and the same could be updated with N/A in StorCli
+SCGCQ00484230 - (Closed) - "Cli /ex/sx set offline" fails with errcd -1 and message enclosure ID not found.
+SCGCQ00495121 - (Closed) - Unable to set pnpid using the ini file with captal letters mixed in the string
+SCGCQ00330250 - (Closed) - StorCLI compliance with OSSRB recommendation
+SCGCQ00342399 - (Implemented) - CSET: (Tbolt PR 211180) Punctured Block Logging Improvements
+SCGCQ00329470 - (Closed) - Implemented the StorCLI commands to erase contents from NVCache
+SCGCQ00488282 - (Implemented) - Add ability to change/program PCIDATA in StorClio (CLI for OEMs)
+SCGCQ00501189 - (Implemented) - MWCLI. Add command /cX/vX locate
+SCGCQ00323426 - (Implemented) - Porting of Vogel 1.0 PRs to storcli phase 2.5 [Libmods]
+SCGCQ00349599 - (Implemented) - Refer attached design doc
+SCGCQ00352120 - (Implemented) - MWCLI. Add HA support into storcli
+SCGCQ00329469 - (Closed) - Implemented the StorCLI commands to scrub memory on controllers
+SCGCQ00332606 - (Implemented) - Display Drive Model number, Serial Number and Firmware Revision as in MSM
+SCGCQ00349548 - (Closed) - Uneven span support is added in StorCLI.
+SCGCQ00351234 - (Implemented) - Provide a way to enable or disable 512E using Applications
+SCGCQ00479543 - (Implemented) - MWCLI: Need MegaOEM for Solaris x86 and Solaris SPARC
+SCGCQ00333213 - (Closed) - Implemented 128 drive support by using the new ENCL_INFO structures
+SCGCQ00322837 - (Closed) - Printing multiple json objects from different controllers as a single Array
+SCGCQ00332600 - (Implemented) - StorCLI compliance with OSSRB recommendation
+SCGCQ00350668 - (Implemented) - Create Spanned R0 array (00) in StorCLI
+SCGCQ00381311 - (Implemented) - dcmd path chagnes for supporting the new cachevault api
+SCGCQ00369742 - (Implemented) - MWCLI. R10, R50, R60, R00 VD creation
+SCGCQ00381093 - (Implemented) - PR SCGCQ00319011: Rebuild time reset
+SCGCQ00433703 - (Implemented) - Megacli/storcli support for lmrc driver
+SCGCQ00413856 - (Port_Complete) - remove the "Drive write cache" policy from Pd information.
+SCGCQ00469192 - (Port_Complete) - Aligning with FW for strip calculation for 4K drives
+SCGCQ00471590 - (Port_Complete) - Need to remove storcli /cx show clusterenable and storcli /cx set clusterenable=<value> since FW did not support this in HA
+SCGCQ00504584 - (Port_Complete) - Command "./storcli /call/eall/sall show" fails for second controller with description drive not found.
+SCGCQ00413017 - (Port_Complete) - Storcli reports "segmentation fault" when running command to downgrade controller to iMR
+SCGCQ00376240 - (Port_Complete) - System halts on issuing storcli commands in EFI Environment.
+SCGCQ00437065 - (Port_Complete) - Driver Version is not shown
+SCGCQ00473065 - (Port_Complete) - StorCli_6.1: The SATA drive is dropped while creating a R1 vd using mix of SAS and SATA drives
+SCGCQ00478786 - (Port_Complete) - (v 1.04.11) get a good return code (0) even when it failed
+SCGCQ00471582 - (Port_Complete) - Storclio:Spelling mistake during execution of command 'compare factorysettings'
+SCGCQ00475598 - (Port_Complete) - Storcli:4K -Wrong size updated after performing OCE on 4K Drives .
+SCGCQ00475601 - (Port_Complete) - storcli crash while using the command /cx/vx expand size=xx expandarray
+SCGCQ00414383 - (Port_Complete) - When a command fails, subsequent commands/actions are aborted in storcli (MegaCli)
+SCGCQ00481849 - (Port_Complete) - StorCLI- StorCLI reports wrong capacitance value for supercap FBU03
+SCGCQ00412593 - (Port_Complete) - Resolving compiler errors for Ctrl-R
+SCGCQ00471048 - (Active) - HA : StorCLI crash when update drive firmware
+SCGCQ00469390 - (Port_Complete) - MR_Inv_6.1:StoreCLI- StorCLI reports retention time as 0 for supercap FBU02 and FBU03
+
+
+Installation Commands:
+=======================
+Any OS specific instructions are noted in a readme file included in a folder in the zip file.
+Refer to the MegaRAID SAS Software User's Guide for any additional StorCLI information.  The User Guide can be found in the MegaRAID Documentation section of www.lsi.com.
+
+
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 09/23/13
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.05.07
+Previous Versoin       1.04.07
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+Solaris x86
+FreeBSD
+EFI
+Ubuntu
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+SCGCQ00009501 - (Closed) - MPI2_FW_IMAGE_HEADER is 16 bits too long
+SCGCQ00183867 - (Closed) - MPI2: IO Unit Page 10 structure incorrect
+SCGCQ00364332 - (Closed) - iMR_Inv_6.1:StoreCLI-StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller
+SCGCQ00374336 - (Closed) - System halts on issuing storcli commands in EFI Environment.
+SCGCQ00374732 - (Closed) - StorCLI cannot set "bypasserror" or "be"
+SCGCQ00374733 - (Closed) - Storcli does not show 512 strip size in the online help
+SCGCQ00378124 - (Closed) - Porting of AdpRestart Command
+SCGCQ00379046 - (Closed) - MegaCLI help shows Storcli in generic help command
+SCGCQ00379112 - (Closed) - storcli-legacy: The helpfile for "adpfwflash" needs to be updated for "NoVerChk"
+SCGCQ00381383 - (Closed) - Storcli_Invader: "/c0 pause pr" Description message should be sync with command
+SCGCQ00394588 - (Closed) - storcli only displays 1 vd when 7 present on DG view
+SCGCQ00397280 - (Closed) - StorCli_MR:Need to modify the "DIMMER SWITCH" Help Description
+SCGCQ00397877 - (Closed) - SWR: EFI:"Press any key to continue" displays twice.
+SCGCQ00397893 - (Resolved) - SWR: EFI: Operating system details shows nothing.
+SCGCQ00399897 - (Closed) - BBU GasGauge Status information should not get printed for TMMC
+SCGCQ00400429 - (Closed) - Storcli help lists unsupported /Fx option for foreign commands
+SCGCQ00406358 - (Closed) - CLI does not provide appropriate error message and error code when secure erase is not supported
+SCGCQ00414300 - (Closed) - StorCli_6.0-The help file for "storcli /cx/fx " is missing.
+SCGCQ00415814 - (Closed) - storcli only associates 38 out of 48 VDs
+SCGCQ00418295 - (Closed) - size=0 VD is getting created with remaining free space, when a VD is present in Drive Group.
+SCGCQ00421114 - (Closed) - Storcli/Storclif/storclio:Help file for Legacy commands displays mrcli instead storcli.
+SCGCQ00421282 - (Closed) - StorCLIO : not able to get or set hwdevice information with storCLIO
+SCGCQ00423757 - (Closed) - EFI: Storcli : Not able to get and set vpd information on TMM module or Supercap
+SCGCQ00435852 - (Closed) - misspelled word in storcli.efi message
+SCGCQ00437754 - (Closed) - Help syntax is not aligned with 80 char per line limits.
+SCGCQ00449926 - (Closed) - Power Shell support for megacli syntax for windows _ Porting
+SCGCQ00450496 - (Closed) - StorcliF : output for the command /c0 compare factorysettings is not in sync with the legacy output.
+SCGCQ00456135 - (Closed) - Unable to create Cachecade VD by referring the syntax in Help file for ''add vd'' .
+SCGCQ00462959 - (Closed) - Slow to create VD in HA Linux
+SCGCQ00466519 - (Closed) - StorCLI_6.1:The help file for "/c0 compare securitykey h" is missing
+SCGCQ00372155 - (Closed) - Certain controller features displayed under "show all" exceeds 80-char limit.
+SCGCQ00374118 - (Closed) - StorCli-"/c0/dall show all "in FreeSpaceDetails legend missing for "ID/VD/AfterVD"
+SCGCQ00374979 - (Closed) - Storcli ld info command displays R10 vd Span Depth to 1.
+SCGCQ00376643 - (Closed) - Fail to set/disable the Disk Cache Policy along with the vd creation.
+SCGCQ00378135 - (Closed) - portings of AdpRestart command
+SCGCQ00378828 - (Closed) - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.
+SCGCQ00385101 - (Closed) - StorCli implementation of AdpRestart Command
+SCGCQ00386429 - (Closed) - StorCLI help file shows /cx/dx show cachecade instead of /cx/dall show cachecade
+SCGCQ00391731 - (Closed) - storcli displays message as firmware flash successfully completed even the flashing is failed.
+SCGCQ00397014 - (Closed) - With one VD as foreign, StorCLI shows all VDs as foreign.
+SCGCQ00397269 - (Closed) - StorCli_5.7: On SuperCap battery ''strat learn" operation is not allowed
+SCGCQ00399002 - (Closed) - handleTokens(tokenListPtr);
+SCGCQ00399387 - (Closed) - Not able to find range for Perf Mode value
+SCGCQ00401663 - (Closed) - help text not working for the command set securitykey
+SCGCQ00412827 - (Closed) - CV (CacheVault) does not support changing bbu mode but StorCLI show option to change bbu mode
+SCGCQ00417435 - (Closed) - StorCLIF : the command /cx get hwdevice fails to get VPD information.
+SCGCQ00417973 - (Closed) - Storclio/Storclif-Detailed help for the command start diag required .
+SCGCQ00423781 - (Closed) - StorCLIF : getting wrong values for get gas gauge information.
+SCGCQ00441696 - (Closed) - StoreCLI- Inconsistent behavior across different application when creating cachecade VD
+SCGCQ00466251 - (Closed) - HA : StorCLI crash when update drive firmware
+SCGCQ00467119 - (Resolved) - SWR_SLES_11_SP3_GM Release validation : In storCli " serial number and FW package Build " fields are showing blank
+SCGCQ00469179 - (Closed) - Aligning with FW for strip calculation for 4K drives
+SCGCQ00372264 - (Closed) - StorCLI: The legend for "phy Error Counters" exceeds the 80-char limit.
+SCGCQ00374377 - (Closed) - GetGGEEPData equivalent syntax is not present in storcli
+SCGCQ00374418 - (Closed) - Storcli : controller information query is displaying the status as failure.
+SCGCQ00375757 - (Closed) - "StorCLI /cx/bbu show modes" show the bbu modes description without the actual bbu mode number
+SCGCQ00377364 - (Closed) - StorCli shows Power Saving Option as enabled, despite controller having power saving option completely disabled.
+SCGCQ00380889 - (Closed) - Not able to set securitykey on controller
+SCGCQ00381100 - (Resolved) - MR: not able to create PRL11 using 96 drives.
+SCGCQ00383043 - (Closed) - StorCLI-Invader : The "coercion" mode is not in sync with the legacy values.
+SCGCQ00384644 - (Resolved) - iMR_Inv_6.1:StorCLI- StorCLI does not show 'Unsupported/Blocked' state for 4K drives even though FW is not supporting 4K
+SCGCQ00386586 - (Closed) - include support for SWR controllers in non LSI verison of storcli.
+SCGCQ00394127 - (Closed) - Added the command to DOS SCU
+SCGCQ00394883 - (Closed) - StorCli_MR: While Creating RAID1 with four drives command facing the "C0:BAIL_OUT at line 1354"
+SCGCQ00396303 - (Resolved) - Cfgclr command fails without force option in Sparc OS
+SCGCQ00400019 - (Closed) - "storcli /c0/dall show" command not working
+SCGCQ00411501 - (Closed) - StorCli_MR: Cache vault Strart learn command displaying twice in the hep file "/c0/cv h"
+SCGCQ00414328 - (Closed) - Perf mode value not getting set when executed along with the other parameters
+SCGCQ00414731 - (Closed) - Checking in StorcliF & storcli0 changes
+SCGCQ00415454 - (Closed) - StorCLI help file does not display "add vd spanned array"
+SCGCQ00420040 - (Closed) - StorCLIF : Not able to read or write factory settings with adpsettings command (legacy command )
+SCGCQ00436928 - (Closed) - Illusive/Bad Data Extracted
+SCGCQ00437762 - (Closed) - Exit code coming as 1 for adpbios (Megacli Syntax)
+SCGCQ00443072 - (Closed) - SWR: In Store Cli if we start any background operation Estimated time left field showing Blank
+SCGCQ00447686 - (Closed) - Storecli does not display complete information for the command ./storecli /c0/p0-x show.
+SCGCQ00456501 - (Closed) - StorcliF: StorcliF and StorcliO crashes when given invalid file for the command /c0 set factorysettings file=filename
+SCGCQ00460861 - (Closed) - MR_Inv_6.1:StorCLI- Gives wrong message after battery retention test command is issued for Supercap FBU03
+SCGCQ00466038 - (Closed) - MR_Inv_6.1:StoreCLI- StorCLI reports retention time as 0 for supercap FBU02 and FBU03
+SCGCQ00469162 - (Closed) - In virtual drives information the Cac filed values are incorrect with regular VD's
+SCGCQ00379157 - (Closed) - StorCLI: the help file for "storcli /cx transform iMR" is missing
+SCGCQ00380143 - (Closed) - The set phy linkspeed operation needs to have the unit(GB/s) mentioned and the Description" column is blank for set and Show.
+SCGCQ00394952 - (Closed) - Segmentation fault hitting while executing the command "/c0 set bgi h "
+SCGCQ00398246 - (Closed) - VD create syntax display improper output.
+SCGCQ00398992 - (Closed) - Command displayed in the same line after "Press any key to continue".
+SCGCQ00402499 - (Closed) - Storecli /c0 show eventloginfo
+SCGCQ00403335 - (Closed) - Mismatch of "Start Copyback " command in global help file and particular help file of copyback .
+SCGCQ00436538 - (Closed) - pd version is not listing all if PDs are missing
+SCGCQ00442610 - (Closed) - Onfi_patch_6.0:Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6.
+SCGCQ00447972 - (Closed) - Storcli : adpgetprop command for enableeug/enableeghsp showing success and not getting reflected when we give wrong flag
+SCGCQ00451393 - (Closed) - Megascu adpm0flash command hangs for Dell controllers.
+SCGCQ00462885 - (Closed) - Need to remove storcli /cx show clusterenable and storcli /cx set clusterenable=<value> since FW did not support this in HA
+SCGCQ00364097 - (Resolved) - iMR_Inv_6.1:StoreCLI- StoreCLI reports wrong Emulation type for VDs
+SCGCQ00375625 - (Closed) - StorCLI : Displaying failure in the output for querying Dimmer switch information
+SCGCQ00379104 - (Closed) - Not able to get paged view of StorCLI output on VM-Ware Platform
+SCGCQ00390777 - (Closed) - iMR_Inv_6.1:StorCLI- VD creation command does not give any message if we tried to create a PI VD using normal PDs
+SCGCQ00392598 - (Closed) - Pause operation should be sync with in show status of the PR.
+SCGCQ00392686 - (Closed) - For the perfmode command in the help file we are displaying the storcli.exe /cx set perfmode = <value> syntax
+SCGCQ00393442 - (Closed) - Spelling mistake in keyword headlessSafeMode
+SCGCQ00406580 - (Closed) - Adprestart command fails
+SCGCQ00413803 - (Closed) - Factory Command /c0/bbu start retentiontest should not be supported in storcli
+SCGCQ00438350 - (Closed) - Megacli crashes after invoking any command in system with one 9280-8e and 2 quad port qlogic FC cards.
+SCGCQ00457906 - (Closed) - storcli_6.1:The help file for"./storcli /cx/mx set h " is missing
+SCGCQ00374735 - (Closed) - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached
+SCGCQ00380746 - (Closed) - Error handling for Drive FW download when the hardware is not supported.
+SCGCQ00384729 - (Closed) - Storcli-Inv-multiple VD's in same DG, setting security using /cx/vall set security=on is Failing for every VD except 1st VD
+SCGCQ00392501 - (Closed) - StorCli_5.7 : "/c0/bbu start learn h " is not showing.
+SCGCQ00394005 - (Closed) - Enabling OCR from StorCLI actually disables the controller property.
+SCGCQ00394375 - (Closed) - Adprestart command fails
+SCGCQ00397920 - (Closed) - StorCli_MR: BBU Strart learn command displaying twice in the "/c0/bbu h"
+SCGCQ00400025 - (Closed) - Storcli shows inaccurate Elapsed Time as recon progresses
+SCGCQ00400640 - (Closed) - Copyright information is showing wrongly
+SCGCQ00408070 - (Closed) - StorCLI does not show both "Current Write Policy" and "Default Write Policy" for VD
+SCGCQ00423347 - (Closed) - Storclif :Segmentation Fault with execution of legacy command BBUMFGSET .
+SCGCQ00423832 - (Closed) - EFI_ Storcli: Cannot set vpd file on controller, EFI hangs and cannot proceed for further operations until reboot
+SCGCQ00433513 - (Closed) - StorcliF : Not able to get or set connector mode on cassiopeia controller
+SCGCQ00436931 - (Closed) - CLI displays VPD data for TMM and Battery/Supercap = ONLY TMM Data Extracted but NOT Supercap Data
+SCGCQ00449134 - (Closed) - Battery Over-temp is not showing correctly.
+SCGCQ00454427 - (Closed) - Storcli_6.1:"press any key to continue" showing twice in the lagacy command
+SCGCQ00464708 - (Closed) - Storcli display total number of VDs in a individual drive group properties.
+SCGCQ00369258 - (Closed) - Description is shown as "None" when using verchk option while flashing fw.
+SCGCQ00392053 - (Closed) - MegaCLI and StorCLI should display "Estimated Time Left" in hours, days and minutes format.
+SCGCQ00396665 - (Closed) - StorcLi_5.7: Remove the description for "Ra=Read Ahead Adaptive" in VD show info.
+SCGCQ00397663 - (Closed) - StorCli_MR: While creating VD using default values FW allows read policy as"Ra=Read Ahead Adaptive" as against PR-317400
+SCGCQ00399443 - (Closed) - StorCLI App Crash while execution of event info for vd ccincon
+SCGCQ00402910 - (Closed) - StorCli_6.0:Raid level can be created even wthout delimiter(i.e size=1gb1gb1gb1gb)
+SCGCQ00424978 - (Closed) - Is VD Emulated=Yes when emulationType=1
+SCGCQ00436107 - (Closed) - The bootwithpinnedcache logic is backwards, both storcli and the FW are affected
+SCGCQ00448094 - (Closed) - core dump while issuing storcli command ./storcli /c0/fall show all.
+SCGCQ00454971 - (Closed) - storcli /c0 show is not listinf SWR controller
+SCGCQ00378448 - (Closed) - StorCLI reports incorrect message when download a firmware image to the controller with pinned cache
+SCGCQ00395178 - (Closed) - storcli doesnt support legacy MegaCli elf commands
+SCGCQ00400139 - (Closed) - StorCLI shows date of manufacture in non-convention format
+SCGCQ00413789 - (Closed) - storcli crashes on having a non PI drive and trying to create pi vd on all the drive
+SCGCQ00422006 - (Closed) - Storcli crashes when given wrong in put file to set VPD on controller
+SCGCQ00442444 - (Closed) - MR_Inv_6.1:StoreCLI- StorCLI gives wrong info when preserved cache is generated on 4K VD (./storcli /c0 show preservedcache).
+SCGCQ00442652 - (Closed) - SWR_1.34 - Serial number field is blank in controller information and the same could be updated with N/A in StorCli
+SCGCQ00066241 - (Closed) - MPI 2.5: Power Management
+SCGCQ00308453 - (Closed) - MPI2: IR reporting Elapsed Seconds
+SCGCQ00299943 - (Closed) - MPI2: add IOCExceptions bit for Partial Memory Failure
+SCGCQ00250721 - (Closed) - MPI2: Update Hard Reset Algorithm with new timings
+SCGCQ00209048 - (Closed) - MPI2: Return Port info in the SAS Device Status Change Event
+SCGCQ00201727 - (Closed) - MPI2: Add spin-up disable bit to SAS IO Unit Page 4
+SCGCQ00201203 - (Closed) - MPI2: Remove/Obsolete MPI Power Management Control Feature PCIE_LINK
+SCGCQ00194293 - (Closed) - MPI2: product specific range for extended image type
+SCGCQ00116336 - (Closed) - Gen 3: method to enable/disable FastPath capability on a per-device basis
+SCGCQ00125672 - (Closed) - Gen 3: add 12Gb/s option for link rate
+SCGCQ00125683 - (Closed) - MPI2: add Link Rate of UNSUPPORTED_PHY_ATTACHED
+SCGCQ00136677 - (Closed) - Gen3: add optional vendor-unique region to MPI25_SCSI_IO_REQUEST structure
+SCGCQ00137514 - (Closed) - MPI2: add PCI Device ID for Warhawk
+SCGCQ00138259 - (Closed) - MPI2: add alternative defines for SGE Direction bit
+SCGCQ00140397 - (Closed) - MPI2: modify Host Based Discovery Action Request
+SCGCQ00141834 - (Closed) - MPI2: ability to disable SATA NCQ on a per-device basis
+SCGCQ00155192 - (Closed) - MPI 2.5: update PCI Device Ids for Invader / Fury
+SCGCQ00157968 - (Closed) - MPI2: Add new Config Page Type - Extended Manufacturing
+SCGCQ00159010 - (Closed) - MPI2: MFG 7 update: method to link ISTWI devices, GPIO, PHYs of a SAS connector
+SCGCQ00160485 - (Closed) - MPI2: Change MPI Simple SGE Local bit description and IEEE Chain Flags to match HW
+SCGCQ00161661 - (Closed) - MPI2: Add IOC Temperature Monitoring Capability
+SCGCQ00162562 - (Closed) - MPI2: rework Pinout field of ConnectorInfo for MFG Page 7
+SCGCQ00162597 - (Closed) - MPI2: reserve some FWDownload ImageType values for product-specific use
+SCGCQ00163413 - (Closed) - MPI2: IOUnit page 7: Add new fields for Board temperature
+SCGCQ00163641 - (Closed) - MPI 2.5: SCSI Initiator I/O path counters (SAS IO Unit Page 16)
+SCGCQ00164407 - (Closed) - MPI 2.5: review SGE Flags for Local bit and Data Location Address Space changes
+SCGCQ00166171 - (Closed) - MPI2: new event for NOTIFY(Enable Spinup)
+SCGCQ00176893 - (Closed) - MPI 2.5: new Power Performance Change Event to report changes to global power management mode
+SCGCQ00177635 - (Closed) - MPI 2.5: report offset of first EEDP error in SCSI IO Reply
+SCGCQ00268818 - (Closed) - Allow for MPI 2.5 IEEE Chain Element in SATA Passthrough Request
+SCGCQ00283196 - (Closed) - Toolbox Diagnostic CLI Request now uses IEEE SGL, including chain elements
+SCGCQ00378774 - (Implemented) - new storcli object is added to storcli to represent cachevault
+SCGCQ00413314 - (Implemented) - Implement storclif commands - get/set hwdevice and configpage
+SCGCQ00413317 - (Implemented) - Implementation of StorCLIF command for AdpSetSubOEMId XX -aN and AdpGetSubOEMId -aN
+SCGCQ00421090 - (Closed) - Added the HA code to MR5.8 stream
+SCGCQ00425077 - (Implemented) - Set factory default command in StorCLI
+SCGCQ00283198 - (Closed) - MPI2: Toolbox Diagnostic CLI Tool Request may now use chain elements in the SGL
+SCGCQ00258327 - (Closed) - MPI2: Reserve Product Specific range for Event codes
+SCGCQ00229719 - (Closed) - MPI2: BIOS Page 1 additions for UEFI HII
+SCGCQ00228572 - (Closed) - MPI2: add 4K sectors supported bit to IOC Page 6 CapabilitiesFlags field
+SCGCQ00203886 - (Closed) - MPI2: New RAID Action (COMPATIBILITY_CHECK)
+SCGCQ00194461 - (Closed) - MPI2: Add auto reserve and 8-kbit seeprom support to ISTWII
+SCGCQ00128142 - (Closed) - Gen 3: update MPI v2.5 header files
+SCGCQ00132183 - (Closed) - MPI2: add optional vendor-unique region to MPI2_SCSI_IO_REQUEST structure
+SCGCQ00136201 - (Closed) - MPI2 - additional IR status information
+SCGCQ00142578 - (Closed) - MPI2: obsolete MPI2_IOUNITPAGE1_MULTI_PATHING
+SCGCQ00169936 - (Closed) - MPI 2.5: remove Command Determines Data Direction bit from SCSI IO
+SCGCQ00172984 - (Closed) - MPI2: for SRIOV, allow PF to access config pages for other VFs
+SCGCQ00175997 - (Closed) - MPI2: Add IO Unit Page 10 - Host Credit Balancing
+SCGCQ00218764 - (Closed) - MPI2: new name for SCSI IO Request Control bits
+SCGCQ00227491 - (Closed) - MPI 2.5: IR - new Raid Action to enable the Fast Path
+SCGCQ00209055 - (Closed) - MPI2: create product-specific range for RAID Action Request
+SCGCQ00125496 - (Closed) - Gen 3: remove Release On Full option for diag trace buffer
+SCGCQ00159395 - (Closed) - MPI 2.5: Obsolete MPI2_RAID_VOL_CREATION_BACKGROUND_INIT
+SCGCQ00175743 - (Closed) - MPI2: method to communicate between hosts on virtual functions
+SCGCQ00433477 - (Implemented) - Mapping of MegaCLI(DPMenable(set/get) & ForceSGPIO(get/set) command to StorCLI( (show/set -> DPM) & (show/set SGPIOforce))
+SCGCQ00438735 - (Closed) - Changed the storcli syntaxes as Suggested by PDM's and FAE's.
+SCGCQ00157982 - (Closed) - MPI 2.5: Chain SGL Segment sizes
+SCGCQ00399602 - (Implemented) - storcli support for LSI and OEM, factory
+SCGCQ00412981 - (Implemented) - implementation of StorcliF commands for adpsetsasa,adpdiag,adpshutdown
+SCGCQ00435665 - (Implemented) - storcli mapping for the missing legacy commands
+SCGCQ00125662 - (Closed) - MPI2: review Task Set Full handling
+SCGCQ00353002 - (Implemented) - Signed FW Update
+SCGCQ00375811 - (Closed) - Need MegaSCU for changes in MFC
+SCGCQ00380155 - (Implemented) - Undo - blocking firmware update for drives behind ALTA
+SCGCQ00413337 - (Implemented) - MWCLI. storcli builds for LSI and OEM factory, please check description.
+SCGCQ00137489 - (Closed) - MPI2: bring Diagnostic Data Upload Tool forward from MPI v1.5
+SCGCQ00379169 - (Implemented) - Remove support for flashing firmware on PDs behind ALTA
+SCGCQ00413064 - (Implemented) - Implementation of MegaSCU commands in storcli syntax
+SCGCQ00413432 - (Closed) - Implementation of commands mentioned in the desc below
+SCGCQ00441143 - (Implemented) - Implementing Bad block management related comands in storcli.
+SCGCQ00369601 - (Implemented) - MWCLI. Add -adpbattest capability to EFI CLI
+SCGCQ00369604 - (Implemented) - Rebuild time reset
+SCGCQ00381311 - (Implemented) - dcmd path chagnes for supporting the new cachevault api
+SCGCQ00419161 - (Implemented) - Implementation of StorCLIO command for ADPMFGSET -f file a0 in storcli
+SCGCQ00419336 - (Implemented) - Implementation of setPcilinkspeed command in storCLIF
+SCGCQ00423256 - (Closed) - RRB 45 - CLI Reporting of TMM VPD
+SCGCQ00369742 - (Implemented) - MWCLI. R10, R50, R60, R00 VD creation
+SCGCQ00381093 - (Implemented) - PR SCGCQ00319011: Rebuild time reset
+SCGCQ00433703 - (Implemented) - Megacli/storcli support for lmrc driver
+SCGCQ00434744 - (Implemented) - Equivalent storcli command implementation of MegaCLI -AdpGetPciInfo -aN|-a0,1,2|-aALL
+SCGCQ00447069 - (Implemented) - Implementation of StorCLIO command for Adpnvram clear a0 in storclio as well as support legacy command
+SCGCQ00413330 - (Port_Complete) - Storcli reports "segmentation fault" when running command to downgrade controller to iMR
+SCGCQ00413856 - (Port_Complete) - remove the "Drive write cache" policy from Pd information.
+SCGCQ00417917 - (Port_Complete) - UEFI StorCli doesn't show the correct UEFI Driver Version
+SCGCQ00413017 - (Port_Complete) - Storcli reports "segmentation fault" when running command to downgrade controller to iMR
+SCGCQ00413888 - (Port_Complete) - StorCli_6.0-The help file for "storcli /cx/dx set security " is missing
+SCGCQ00376240 - (Port_Complete) - System halts on issuing storcli commands in EFI Environment.
+SCGCQ00411384 - (Port_Complete) - Unable to start migration from R0 to R5
+SCGCQ00411614 - (Port_Complete) - hits segmentation fault while creating multiple Vd's on Raid 10.
+SCGCQ00413311 - (Port_Complete) - Cannot change or update controller date and time in MegaSCU
+SCGCQ00437065 - (Port_Complete) - Driver Version is not shown
+SCGCQ00375839 - (Active) - StorCLI: The legend for "phy Error Counters" exceeds the 80-char limit.
+SCGCQ00411449 - (Port_Complete) - Improper output when configure R10 VD.
+SCGCQ00414863 - (Port_Complete) - When a command fails, subsequent commands/actions are aborted in storcli (MegaCli)
+SCGCQ00413041 - (Port_Complete) - Getting error message while installing or upgrading on Linux platform
+SCGCQ00458499 - (Port_Complete) - Block configuration with unsupported strip element sizes
+SCGCQ00414383 - (Port_Complete) - When a command fails, subsequent commands/actions are aborted in storcli (MegaCli)
+SCGCQ00391744 - (Active) - StorCli-"show ctrlcount" help is not displaying.
+SCGCQ00412593 - (Port_Complete) - Resolving compiler errors for Ctrl-R
+SCGCQ00425263 - (Active) - storcli /c0 show all : did not have HA information+request to add additional info
+
+
+Installation Commands:
+=======================
+Refer to the User's Guide included in the package.
+
+
+
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 05/30/13
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.04.07
+Previous Versoin       1.03.11
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+Solaris
+FreeBSD
+EFI
+Ubuntu
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+SCGCQ00364332 - (Closed) - StoreCLI does not give proper message while trying to create 33rd VD on iMR FURY controller
+SCGCQ00374336 - (Closed) - System halts on issuing storcli commands in EFI Environment.
+SCGCQ00374732 - (Closed) - StorCLI cannot set "bypasserror" or "be"
+SCGCQ00374733 - (Closed) - Storcli does not show 512 strip size in the online help
+SCGCQ00378124 - (Closed) - Porting of AdpRestart Command
+SCGCQ00372155 - (Closed) - Certain controller features displayed under "show all" exceeds 80-char limit.
+SCGCQ00374118 - (Closed) - StorCli-"/c0/dall show all "in FreeSpaceDetails legend missing for "ID/VD/AfterVD"
+SCGCQ00378135 - (Closed) - portings of AdpRestart command
+SCGCQ00378828 - (Closed) - StorCLI-Legacy:'adpbootdrive get' fails to get bootdrive information.
+SCGCQ00372264 - (Closed) - StorCLI: The legend for "phy Error Counters" exceeds the 80-char limit.
+SCGCQ00374418 - (Closed) - Storcli : controller information query for OEM controller is displaying the status as failure.
+SCGCQ00375757 - (Closed) - "StorCLI /cx/bbu show modes" show the bbu modes description without the actual bbu mode number
+SCGCQ00374735 - (Closed) - StorCLI crashed when run on a Windows 2008 64-bit with 24GB of RAM and 66 drives attached
+SCGCQ00380746 - (Closed) - Error handling for Drive FW download when the hardware is not supported.
+SCGCQ00369258 - (Closed) - Description is shown as "None" when using verchk option while flashing fw.
+SCGCQ00378448 - (Closed) - StorCLI reports incorrect message when download a firmware image to the controller with pinned cache
+SCGCQ00375811 - (Implemented) - Need MegaSCU for changes in MFC
+SCGCQ00380155 - (Implemented) - Undo - blocking firmware update for drives behind interposer
+SCGCQ00379169 - (Implemented) - Remove support for flashing firmware on PDs behind interposer
+SCGCQ00375839 - (Active) - StorCLI: The legend for "phy Error Counters" exceeds the 80-char limit.
+
+Installation Commands:
+=======================
+Refer to the User's Guide included in the package.
+
+
+
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 03/02/13
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.03.11
+Previous Versoin       1.02.08
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+Solaris
+FreeBSD
+EFI
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+SCGCQ00339670 - (Completed) - Fixing Linux Release 1.02-00
+SCGCQ00359141 - (Completed) - Fixing Linux Release 1.03.01
+
+
+Installation Commands:
+=======================
+Refer to the User's Guide included in the package.
+
+
+
+
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 01/16/13
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.02.08 (Phase 3)
+Previous Version       1.01.10 (Phase 2)
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+Solaris
+FreeBSD
+EFI (EFI StorCLI version 2.5.1.02.05)
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+There were few updates in command syntaxes.
+-      See revision history in Rev E : available in Page 2 of user guide(StorCLI_Phase3_RefMan_.pdf)
+-      See revision history in appendix D: available in Page 76 of user guide(StorCLI_Phase3_RefMan_.pdf)
+SCGCQ00295690  MWCLI. Solaris x86 support
+SCGCQ00295810  MWCLI for uEFI
+SCGCQ00314895  MWCLI. FreeBSD 7.x & 8.x support
+Fixes since Phase 2 Release...
+SCGCQ00374892  XD1.5-StorCLI attempts to Add/remove configure/unconfigured VDs when add/removal of ALL vds is issued.
+SCGCQ00355952  StorCLI : Not able to set CC scheduling beyond some limit.
+SCGCQ00356883  Storcli - legacy commands related to bbu failing in multicontroller environment
+SCGCQ00345353  storcli /c0/ex show status---> It is not displaying all the information of the enclosure.
+SCGCQ00356970  StorCLI: The time remaining column is not populated on executing "storcli /c0 show aso" and no description for "Mode" column.
+SCGCQ00358752  StorCLI: "/c0 show" command displays PD LIST table information occupying more than 80 coloumns
+SCGCQ00360027  StorCli-Incorrect VD size displayed after expansion of VD size.
+SCGCQ00335385  Storcli command won't display any controllers
+SCGCQ00339764  StorCLI_EFI : Getting syntax error for add hotsparedrive command.
+SCGCQ00343802  StorCLI_EFI : System halts on performing  RLM (Raid level Migration)  without adding/removing drives, in EFI Environment
+SCGCQ00352972  StorCli- system halted on executing command " storcli /c0/f show"  in UEFI
+SCGCQ00354167  StorCli- "System hang" while creating the VD using legacy command in UEFI
+SCGCQ00354581  Storcli_EFI : System halts while executing lengthy commands
+SCGCQ00315799  4k_DIF: Not able to Replace the missing Drive for 4K VDusing the MegaCLI -Vogel_1.0_sprint_4k Apr 11, 2012
+SCGCQ00315801  Creating the 4K VD fails with firmware error description using MegaCLI -Vogel_1.0_sprint_4k
+SCGCQ00316591  Storcli: Importing Foreign Configuration while Rebuild is in progress Show fall shown multiple R60 VDs
+SCGCQ00316673  Storcli: Query for Phyinfo using storecli twice, will results in non-functional controller/system hang
+SCGCQ00316674  Unable to set abortCConerror property on controller card using StoreCli.
+SCGCQ00316675  Storcli displaying Emergency spare is No for all unconfigured drives while "enableeug" property is ON
+SCGCQ00337971  StorCLI : Not able to schedule PR in EFI environment
+SCGCQ00338386  StorCLI : Not able to upgrade controller firmware  without using nosigchk and noverchk in EFI Environment.
+SCGCQ00338398  StorCLI: getting syntax error for pd insert command in EFI Environment
+SCGCQ00341481  StorCLI - after migration the last pd is getting displayed twice( when migrating from 4pd raid 5 to 6 pd r0 )
+SCGCQ00341581  Set path to new library as "export LD_LIBRARY_PATH=/usr/local/lib" after installing libgcc-3.4.6-sol10-x86-local.pkg
+SCGCQ00341585  fails to log the latest set of events to the file.
+SCGCQ00341991  StorCLI_EFI: Displaying "?" symbol under progress bar when PD Initialization is in progress
+SCGCQ00342017  StorCLI: After a controller FW flash from StorCLI, No pending Images are seen before a reboot as seen in the legacy builds.
+SCGCQ00342072  FreeBSD - Adapter cache Flush is not working .
+SCGCQ00342077  storecli_EFI.storecli.efi /c0/pall set linkspeed=val   It is not displaying PHY info field .
+SCGCQ00342117  StorCli does not display a help message for  "/cx/ex show status h" and storCLI  storcli /cx/ex show all h
+SCGCQ00342241  StorCLI_EFI:Storcli is showing that VD expansion is possible but not allowing to expand if space is before start LBA of VD
+SCGCQ00342272  StorCLI_EFI : Not able to save the configuration with Megacli syntax
+SCGCQ00342670  StorCli-"enblPI/PreventPIImport" equivalent command is not their in StorCLi
+SCGCQ00342693  StorCLI: A Drive spinup/spindown not successful on drives marked as hotspare as against MSM.
+SCGCQ00342730  Storcli_EFI : Not getting valid JSON output for any of the commands in EFI Environment
+SCGCQ00342732  StorCLI: the "set bootdrive = on" command sets the requested vd2 as bootable without user intervention.
+SCGCQ00343591  StorCLI: A dedicated hot spare cannot be assigned to any one of the particular spans for a spanned DG as against MSM.
+SCGCQ00343636  StorCLI allows a single Unconfigured Drive to be assigned as a dedicated hotspare to two different VD's.
+SCGCQ00343799  StorCLI: Cannot explicitly assign the configured cachecade VDs to the Disk Groups for the existing CC-VD.
+SCGCQ00345525  StorCLI: On performing an "add vd" with size provided in TB a decimal value is truncated to whole number as input.
+SCGCQ00345557  StorCLI:  A vd can be assigned to a cachecade VD multiple times also a cachecade VD allows to be assigned to itself.
+SCGCQ00345791  Storcli: not able to flash PD firmware on FreeBSD
+SCGCQ00346878  Storcli: Not getting proper import preview for secured foreign VD on EFI and Solaris Environment.
+SCGCQ00346917  Storcli_EFI : Not able to set securitykey on controller in EFI environment
+SCGCQ00348494  StorCli-" /c0 show stoponerror" is not working
+SCGCQ00350582  StorCli- "Disk Group" column is missing.
+SCGCQ00353580  Storcli- "/c0/fall show" is displaying wrong.
+SCGCQ00353641  StorCLI - spinup/spindown is not supported for tape drive , but executing spindown operation shows success message
+SCGCQ00356700  StorCLI - legacy command adpshutdown not working properly
+SCGCQ00356986  StorCLI - when " stop initialization " command is executed on a pd even when it is not in progress it is showing success
+SCGCQ00357024  StorCLI - flush|flushcache showing command not supported whereas subsequent legacy command working successfully
+SCGCQ00360565  In '/cx/vx show all' Active Operations = None during a Rebuild
+SCGCQ00289586  Emulated Block size should be displayed as part of PD information for 512E drives
+SCGCQ00316676  StorCLI help does not have the information to show the boot drive
+SCGCQ00316680  FreeBSD support for MegaWare Cli
+SCGCQ00318116  StorCLI2.5: "delay" & properties of "Consistency Check" does not function properly
+SCGCQ00320538  iMR_Inv_MegaCli:Deb package fir MegaCli not available for Ubuntu 12.04 OS
+SCGCQ00324813  MegaCLI: MFI_STAT_NOT_FOUND returns when retrieving the FW event log.
+SCGCQ00326760  StorCli adpbbucmd shows next learn cycle would happen 1 day earlier for SuperCaP
+SCGCQ00327419  StorCli-IN help file-"BBU show status" command is not their.
+SCGCQ00327557  Storcli-"BBU show help" is not working.
+SCGCQ00328182  StorCLI2.0: patrolread help description for delay is mentioned in terms of "minutes" instead of "hours"
+SCGCQ00328204  StorCLI- Individual help for VD expansion does not give the completion description .
+SCGCQ00328568  StorCli-"PHY Linkspeed show help/" is not working
+SCGCQ00329941  StorCli-"DRIVER VERSION" is not displaying for SWR controller  on LINUX Platform.
+SCGCQ00330263  StorCli-" show  ds | safeid | rehostinfo help" is not displaying.
+SCGCQ00330447  StorCli-" On VD show cc help " is not displaying
+SCGCQ00335327  storcli 1.01.10 doesn't display all required enclosure info for /cx/ex show all, i.e. voltage/ps/temp/etc status/values
+SCGCQ00337951  Storcli : Exit code is displayed  unnecessarily at the end of output on efi environment .
+SCGCQ00337956  StorCLI: -h is not working for help display in  efi environment
+SCGCQ00337967  StorCLI : getting invalid error code (out of range) while querying for invalid drive number in EFI Environment
+SCGCQ00338155  StorCLI : VD's exluded from CC Scheduling is not reflected properly with /c0 show cc command in EFI Environment
+SCGCQ00338194  StorCli-IN help file-"BBU show properties" command is not their.
+SCGCQ00338206  StorCli- "legacy help file is not displaying"
+SCGCQ00338265  StorCLI: paged view of any output should support " Press any key to continue" to proceed to next page
+SCGCQ00338393  StorCLI : Date and Time of controller is not displayed in proper format in EFI Environment
+SCGCQ00338576  StorCli-"Help page" last line execuite with storcli directory.
+SCGCQ00339730  StorCLI_EFI : In paged output the lines following the message "Press any key to continue" should be displayed in next line.
+SCGCQ00340208  code changes for some StorcliEFI-DEFECT
+SCGCQ00341443  StorCLI - partial help for patrolread delay is not working
+SCGCQ00341451  StorCLI - show patrolread is not showing the progress of the current patrol read in percentage
+SCGCQ00341472  StorCLI - show migrate is not displaying the time since the virtual drive migration started
+SCGCQ00341679  StorCLI : partial help for cc is not working ("/cx show cc h" ) . Giving syntax error
+SCGCQ00342053  storecli_EFI>storecli h  It is displaying description of some commands(use only for partial help).
+SCGCQ00342122  help file is not available for  "storcli dx show all h"
+SCGCQ00342129  storecli_EFI> storecli.efi /c0/ex show status not displaying ALARM info field
+SCGCQ00342144  StorCLI - the command "./storcli /c0 show reconrate " is displaying the migrate rate under controller prop
+SCGCQ00342229  storecli_EFI> After stopping init in multiple vds ,VD status in not updating properly.
+SCGCQ00342461  StorCLI doesn't show NCQ support of a SATA drive
+SCGCQ00342597  StorCli-"Perfmode" value is not mentioned in the description
+SCGCQ00342605  StorCLI does not prompt user intervention while deleting VD which has Boot Partition.
+SCGCQ00342727  Help description for Controller Properties abbrevations like ABS, SOE is missing in cmd O/P
+SCGCQ00342737  Not displaying the correct version of driver in megacli command.
+SCGCQ00342997  StorCLI - not getting partial help for /cx/px set linkspeed h
+SCGCQ00343108  StorCLI_EFI : Not able to disable/enable  Dimmer switch 1 with command /c2 set ds=off/on  type=4
+SCGCQ00343191  StorCLI - cannot get a helpfile for "./storcli /cx set cc h "
+SCGCQ00343199  StorCli-In Help File" show/set OCR" command is not their.
+SCGCQ00343222  FREE BSD- Modifiaction of syntax required in help file for setting consistency check .
+SCGCQ00343682  StorCLI - Syntax of set cc is given wrong in global help file
+SCGCQ00343749  StorCLI: mismatch with help file for setting linkspeed with the that of the error message on setting unsupported linkspeed.
+SCGCQ00343786  StorCLI -  "storcli /cx delete securitykey"when executed twice in a row shows a success status in controller properties
+SCGCQ00344142  The size is in KB for "WithArrExp" instead of GB under EXPANSION INFORMATION
+SCGCQ00344188  Help file not working for 'storcli /cx/vx expand '
+SCGCQ00344707  StorCLI: 512KB Stripe size is not mentioned in CLI  help page of "storcli /cx add vd h"
+SCGCQ00345311  StorCLI - "storcli /cx/pall set linkspeed = 1.5/3 ... " showing success but setting it individual is showing a comand invalid
+SCGCQ00345706  ./storcli /c0 set perfmode=val  ----->It is setting perfmode value other than 0 and 1
+SCGCQ00345907  StorCli-" show aso " command is missing in help file.
+SCGCQ00346025  ./Storcli -AdpGetPciInfo -a0 ---->This command is not displaying information like bus,device,functional no. of the adapter.
+SCGCQ00346919  Storcli_EFI : partial query for commands is not working with numbers like /c0 set h (works only with /cx )
+SCGCQ00348538  StorCli-"Firmware Package Build" version is not showing in controller Info (UEFI)
+SCGCQ00348706  StorCli-"/c0 set ds h" in help description need to some changes.
+SCGCQ00349475  StorCLI: The "gas gauge" needs to be addressed under "show BBU status h"
+SCGCQ00349498  StorCLI: A help file to be added for "storcli /c0/bbu start learn"
+SCGCQ00351169  ./storcli /c0 set securitykey=xxx passphrase=xxx ---->Description of securitykey should be display in description field.
+SCGCQ00351987  Storcli : Unexpected line at output when legacy command ''Adpallinfo'' executed with page=x
+SCGCQ00352560  The help file for "set backplane" needs to be revised.
+SCGCQ00352571  StorCLI: "The set backplane = 0"  the command value description exceeds 80 charecters.
+SCGCQ00352630  STORCLI: Command to set SOE(stop on Error) is missing in global help file
+SCGCQ00352637  StorCLI: Global/Individual help missing for command to set ABS(Auto Boot Select) .
+SCGCQ00352779  User guide PDF file for Technical and Documentation are required to be updated.
+SCGCQ00352887  None of the build is having readme file except solaris in the storcli build ---->ver 1.02-02 Oct 23,2012
+SCGCQ00353682  Storcli- Displaying incomplete foreign config even if all the drives are in Ugood state for /c0/fall show command
+SCGCQ00353683  after controller firmware download completes Description is showing the firmware package version instead of firmware version
+SCGCQ00354235  Storcli: StorCLI  should throw syntax error for the command /c0/dall show all all all
+SCGCQ00354543  StorCLI: help legend missing for "show freespace"
+SCGCQ00355107  StorCLI-Require Update of the URL mentioned in Readme File of SOLARIS11 .
+SCGCQ00355116  Storcli_EFI : Showing success for  non-supported operations,  related with  association of VD to cachepool.
+SCGCQ00355137  Storcli - when setting smartpollinterval to -1 , it is throwing syntax error instead of failure .
+SCGCQ00355367  StorCLI- Description for what kind & range of value will be accepted by memscrubpatterns is not provided in help file
+SCGCQ00355432  StorCLI : Not able to set CC execution delay if used with complete  CC scheduling command
+SCGCQ00356657  Special Charecters are printed or the state info is missing under the state column of the drive.
+SCGCQ00356695  StorCLI - when stop command for PD reated operations  is executed . The command description shows wrong slot id's for PD's
+SCGCQ00356998  Storcli-display command when used with "page" is not showing the output correctly...
+SCGCQ00357319  The "EID:Slot" is not populated on fetching information on the existing foreign configuration.
+SCGCQ00357371  StorCLI: The PD list table is not sorted acoording to enclosureid:slotid.
+SCGCQ00357647  storcli: cliefimain.cpp file changes for lengthy commands.
+SCGCQ00357648  Storcli reports baterry is charging and discharging at the same time.
+SCGCQ00359371  Storcli-"show" info need to add  abbreviation for "PDs/DGs/VDs/BBU/Y"
+SCGCQ00361544  StorCli-"/c0 start pr " in failure state displaying worng 'error message'.
+SCGCQ00364859  Correcting the formats of below commands (exit code ,show event log and time, date format )
+SCGCQ00328185  StorCli-In legacy help file command line execute  along with" press any key to continue"-only Windows OS
+SCGCQ00328531  StorCLI2.0: phy linkspeed help description is mentioned in terms of "GB" instead of "Gb/s"
+SCGCQ00333006  LSI MegaCLI EncInfo (Enclosure Info) duplicates the first power supply status data to both power supplies
+SCGCQ00338675  'VD ADD' should use 'strip' instead of 'stripe'.
+SCGCQ00341595  StorCLI - Spelling mismatch "Alta" specified which should either be "SATA" or "ATA"
+SCGCQ00342071  storcli help command with "Legacy" and "page" option doesnt display the paged help.
+SCGCQ00342978  StorCli-"Phy linkspeed show all help" in description spelling mistake is their.
+SCGCQ00343142  StorCli-"eccbucketleakrate" , the value should be greater than ‘0’ and less than ‘65535’. Help is misleading.
+SCGCQ00344136  Description for option [expandarray] in command storcli /cx/v(x|all) expand Size=<xx> is not clear
+SCGCQ00344150  StorCLI - partial help ( Descripton ) for command "storcli /cx /bbu show properties h " is not there
+SCGCQ00344171  StorCli-"Smartpollinterval"value need to be mention in the Description.
+SCGCQ00344800  Help legend is missing for properties of enclosure in O/P of ./storcli /c0/e59 show all and show cmds
+SCGCQ00344994  StorCLI - "storcli /cx/vx show preservedcache " command is not present in the help file
+SCGCQ00352071  Storcli_EFI : "storcli -h legacy" cmd is not working
+SCGCQ00352881  Alignment text issue in the O/P of command "storcli.efi /c0 show eventlogInfo"
+SCGCQ00359980  Code cleanup in Univ_viva_cli
+SCGCQ00340241  StorCLI - " insert " command is not working
+SCGCQ00338560  StorCLI : Driver version is not displayed correctly
+SCGCQ00339757  StorCLI_EFI : Progress field for drive erase operation is displaying "?' symbol if drive erase is in progress.
+SCGCQ00342762  StorCli-"Driver Version" field is missing (Free BSD 7.3)
+SCGCQ00343005  StorCLI: Stripe Size of the VD is shown incorrect after a PD missing operation is performed on the disk group.
+SCGCQ00346251  storcli does not report ROC temperature in '/cX show all' in HW section
+SCGCQ00354427  StorCli-"System halts" on performing operation "/c0 set aso key=    " in UEFI
+SCGCQ00342052  StorCLI - command "./storcli show " is throwing a description message that command is not supported
+SCGCQ00343169  StorCli-"Show/set OCR help" is not Displaying
+SCGCQ00344861  storecli_EFI > storecli.efi /c0 set perfmode h---> In  perfmode help file it is not giving what values we can set.
+SCGCQ00346944  Storcli: Inquiry data of the drives is missing from output of  /cx/ex/sx show all command on FreeBSD with TB controller
+SCGCQ00354191  Storcli - giving syntax error when trying to get help using numbers , e.g "storcli_efi /c0 h "
+SCGCQ00355847  StorCli- "Serial Number" of physical Drives is not getting displayed in FreeBSD
+SCGCQ00341986  StorCLI: Does not prompt the user to restart/reboot the controller after a FW flash for it to take effect as seen in MSM.
+SCGCQ00348048  StorCLI: StorCLI does not provide single command to perform a locate drive configured as part of a VD as against MSM.
+SCGCQ00348474  .\storCLI64.exe /c1 add vd type=r1 drives=47:1,2 ----> command is giving syntax error if using "comma" for vd creation.
+SCGCQ00350579  StorCLI: The VD name cannot contain spaces as allowed in MSM.
+SCGCQ00358917  EFI Shell StorCLI: Rebuild starts and does not make any progress in EFI env
+SCGCQ00375019  “StorCli64.exe /xd/wdall show” command reports that NytroXD license is absent even when the license is available
+SCGCQ00318433  Porting of Vogel 1.0 PRs to storcli phase 2.5
+SCGCQ00341607  Failing to display Driver Version  in FreeBSd
+SCGCQ00343664  Storcli-"Enclosure Slot No is mis matching "(DE1600-SAS )
+
+
+
+
+
+
+Important Notes:
+==================
+STORCLI PHASE 2.0 Specific Limitations:
+1.     User can use both 'raid0' and 'r0' for mentioning the raid level. And user can find both the forms in the help command.
+2.     When passing parameter,'set' for CC mode is mandatory.
+3.     The use of comma in between array no and row parameter in the syntax for making ‘pdreplacemissing’ should not be used.
+4.     User would not be able to specify ROWs while creating ‘Dedicated Hot Spare’. Instead user needs to use ‘Drive Group ID’ as dgs=N
+5.     In ‘Foreign Configuration show’, utility will display VD as ‘Foreign’ instead of showing the VD state.
+6.     The success code and description is printed only after complete processing of the command. Success will not be printed unless the entire log is displayed to the output. Hence the success code and description is printed at the end of the log for this particular command.
+7.     Any command syntax is still valid, if user uses “-” instead of “/”  for e.g. storcli.exe /c0-vall show.
+8.     Show ‘Bus and PCI Slot type’ are not shown as part of the controller information.
+9.     While creating a VD using non-Enc-ID Devices, user needs to provide inputs in the format ‘D:SlotID’ as syntax (for eg: Drives=D:1,2,3 where 1,2,3 are the slot ids of the non encID devices)
+10.    Tape Drives will be listed only with /c0/sall show all command, /c0/sall show doesn’t list Tape drive but only display the direct attached drives if present or a blank table if none are connected.
+11.    Importing Foreign Configuration while Rebuild is in progress then query for Show fall the output would display multiple R60 VDs.
+12.    Date and Time of controller is not displayed in proper format in EFI Environment
+13.    JSON is not required in EFI
+14.    The sector size of the drives are displayed in “KB” instead of bytes under the PD List table. This is just display error in tabular format but it is displayed correctly in drive details.
+15.    The “Eid:slot” column while importing a foreign config is not populated. StorCLI: The VD name cannot contain spaces as allowed in MSM.
+16.    Consistency Check cannot be scheduled beyond year-2037AD.
+17.    Flashing 9260CV low-level controller firmware is supported only through DOS version of CLI (MegaCLI) and not through EFI version of StorCLI.  Flashing MegaRAID firmware does not have this issue.
+
+Known Behavior:
+1.     ‘All VD initialization’ command when run through StorCLI utility, shows the error message as failed for cachecaded VD. This is a generic limitation.
+2.     While reconstruction is in progress, start of CC/Init/BGI operations on same VD throws an inappropriate error message. This is a generic limitation.
+3.     In controller show cc the field CC current state will change only when it meets the schedule CC parameters.
+4.     All the unsupported commands for SWR controller if tried to execute may result in unknown behavior for example – system hang-up. For the list of unsupported commands refer to user guide Appendix C: Unsupported Commands in Embedded RAID.
+5.     Output for controller information contains junk characters in VMware ESXi 4.1 update2.
+6.     FDE drives are displayed as secured drives on SWR- SCU controller.
+7.     There is no check to see whether user has entered different properties or the same property multiple times in StorCLI command. Hence StorCLI  does not throw syntax error for the command “/c0/dall show all all all”. This issue is because of the implementation of accepting multiple properties in a single command line in some cases.
+
+
+Installation Commands:
+=======================
+Refer to the User's Guide included in the package.
+
+
+
+
+Component:
+=========
+SAS MegaRAID StorCLI
+Release Date: 11/06/12
+
+
+Version Numbers:       StorCLI
+===============                ===========
+Current Version                1.01.10
+
+
+Contents:
+=========
+This package contains StorCLI for the following OSes:
+Windows
+Linux
+VMware
+VMware MN
+
+Use the StorCLI components from the folder that matches your OS.
+
+
+Enhancements and Bug Fixes
+==========================
+Initial Release
+
+
+Important Notes:
+==================
+1.  User can use both ‘raid0’ and ‘r0’ for mentioning the raid level. And user can find both the forms in the help command.
+2.  When passing parameter ‘set' for CC mode is mandatory.
+3.  The use of comma in between array no and row parameter in the syntax for making ‘pdreplacemissing’ should not be used.
+4.  User would not be able to specify ROWs while creating ‘Dedicated Hot Spare’. Instead user needs to use ‘Drive Group ID’ as dgs=N
+5.  In ‘Foreign Configuration show’, utility will display VD as ‘Foreign’ instead of showing the VD state.
+6.  The success code and description is printed only after complete processing of the command. Success will not be printed unless the entire log is displayed to the output. The success code and description is printed at the end of the log for this particular command.
+7.  Any command syntax is still valid, if user uses “-” instead of “/”  (e.g. storcli.exe /c0-vall show.)
+8.  Show ‘Bus and PCI Slot type’ are not shown as part of the controller information.
+9.  While creating a VD using non-Enc-ID Devices, user needs to provide inputs in the format ‘D:SlotID’ as syntax (e.g. Drives=D:1,2,3 where 1,2,3 are the slot ids of the non encID devices.)
+10. Tape Drives will be listed only with /c0/sall show all command. /c0/sall show doesn’t list Tape drive but only displays the direct attached drives if present or a blank table if none are connected.
+11. Importing Foreign Configuration while Rebuild is in progress then query for Show fall the output would display multiple R60 VDs.
+12. For any operation (Migrate/Init/BGI/CC) percentile completed in minutes is not displayed in StorCLI output.
+13. ‘All VD initialization’ command when run through StorCLI utility, shows the error message as failed for cachecaded VD.
+14. While reconstruction is in progress, start of CC/Init/BGI operations on same VD throws an inappropriate error message.
+15. In controller show cc the field CC current state will change only when it meets the schedule CC parameters.
+16. All the unsupported commands for SWR controller if tried to execute may result in unknown behavior for example – system hang-up. For the list of unsupported commands refer to user guide Appendix C: Unsupported Commands in Embedded RAID.
+17. Output for controller information contains junk characters in VMware ESXi 4.1 update2.
+18. FDE drives are displayed as secured drives on SWR- SCU controller.
+
+
+
+Installation Commands:
+=======================
+Refer to the User's Guide included in the package.